Skip to Content

A-DF(ZN)2YT

APPLICATION

The cable is determined for outdoor aerial lines, for building of telecommunication networks, installation of LANs and cable TV networks and information systems in power engineering and industry. The cable can be used for outdoor mounting, for aerial lines between buildings. Typical gap distance between two grips is from 80 up to 300 m. Also cable for greater gap distances can be supplied by agreement.

PROPERTIES

• FULL DIELECTRIC SELFSUPPORTING CONSTRUCTION
• MAX. NUMBER OF FIBRES 48
• MAX. NUMBER OF CORES 6
• ARAMIDE STRENGTH ELEMENTS
• PE JACKET
• FOR GAP DISTANCES FROM 80 UP TO 300 M

The design of cables allows high tensile loads. The filled cores provide very good longitudinal waterproofing. Maximal gap distance depends on wind conditions.

CONSTRUCTION

Pic. 1

 

Transmission element - optical fibre
- single-mode (SM) E9/125
- multimode (G) G50/125, G62,5/125

Secondary protection - loose multi-fibre filled tube

Cores - consisted of filled tubes with fibres, stranded around dielectric central strength element

Strength elements - aramide fibres and dielectric central strength element

Jacket - black polyethylene

Tab. 1 Technical properties

Cable type A-DF(ZN)2YT
Maximal number of cores with fibres 5 6
Number of fibres in tubes 1 to 8 1 to 8
Maximal number of fibres 40 48
Core diameter [mm] 2,4 2,4
Outer diameter [mm] 13 14
Maximal allowed tensile load [N] 8000 8000
Minimal allowed bending radius [mm] 240 260

Permissible temperature range by mounting [°C]

-5 to +60 -5 to +60
Permissible temperature range in service[°C] -40 to +70 -40 to +70
Weight – informative value [kg/m] 130 150
Fibre type E9/125, G50/125, G62,5/125 E9/125, G50/125, G62,5/125
Outer jacket PE black PE black
Typical production lengths [m] 2000, 4000, 6000 2000, 4000, 6000


PACKING, DELIVERING, STORAGE, TRANSPORT

Optical cables are supplied twisted on wooden or metal drums with diameters of 500 to 1500 mm, shorter lengths twisted to coils.

To every supplied length is attached test protocol and tag with these data:

- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control

The whole cable can be marked with description on a jacket on request of a client.

Cables can be stored in general in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them.

It is necessary to assure that cables are not damaged by mechanical or other effects by transport.