A-DF(ZN)2YT
APPLICATION
The cable is determined for outdoor aerial lines, for building of telecommunication networks, installation of LANs and cable TV networks and information systems in power engineering and industry. The cable can be used for outdoor mounting, for aerial lines between buildings. Typical gap distance between two grips is from 80 up to 300 m. Also cable for greater gap distances can be supplied by agreement.
PROPERTIES
• FULL DIELECTRIC SELFSUPPORTING CONSTRUCTION
• MAX. NUMBER OF FIBRES 48
• MAX. NUMBER OF CORES 6
• ARAMIDE STRENGTH ELEMENTS
• PE JACKET
• FOR GAP DISTANCES FROM 80 UP TO 300 M
The design of cables allows high tensile loads. The filled cores provide very good longitudinal waterproofing. Maximal gap distance depends on wind conditions.
CONSTRUCTION
Pic. 1
Transmission element - optical fibre
- single-mode (SM) E9/125
- multimode (G) G50/125, G62,5/125
Secondary protection - loose multi-fibre filled tube
Cores - consisted of filled tubes with fibres, stranded around dielectric central strength element
Strength elements - aramide fibres and dielectric central strength element
Jacket - black polyethylene
Tab. 1 Technical properties
| Cable type A-DF(ZN)2YT | ||
| Maximal number of cores with fibres | 5 | 6 |
| Number of fibres in tubes | 1 to 8 | 1 to 8 |
| Maximal number of fibres | 40 | 48 |
| Core diameter [mm] | 2,4 | 2,4 |
| Outer diameter [mm] | 13 | 14 |
| Maximal allowed tensile load [N] | 8000 | 8000 |
| Minimal allowed bending radius [mm] | 240 | 260 |
|
Permissible temperature range by mounting [°C] |
-5 to +60 | -5 to +60 |
| Permissible temperature range in service[°C] | -40 to +70 | -40 to +70 |
| Weight – informative value [kg/m] | 130 | 150 |
| Fibre type | E9/125, G50/125, G62,5/125 | E9/125, G50/125, G62,5/125 |
| Outer jacket | PE black | PE black |
| Typical production lengths [m] | 2000, 4000, 6000 | 2000, 4000, 6000 |
PACKING, DELIVERING, STORAGE, TRANSPORT
Optical cables are supplied twisted on wooden or metal drums with diameters of 500 to 1500 mm, shorter lengths twisted to coils.
To every supplied length is attached test protocol and tag with these data:
- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control
The whole cable can be marked with description on a jacket on request of a client.
Cables can be stored in general in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them.
It is necessary to assure that cables are not damaged by mechanical or other effects by transport.