APPLICATION

The cable is determined for outdoor lines, for building of telecommunication networks, installation of LANs and cable TV networks and information systems in power engineering and industry.
The cable can be used for outdoor mounting, for aerial lines between buildings. Typical gap distance between two grips is from 60 up to 200 m.


PROPERTIES

• SELFSUPPORTING CONSTRUCTION
• MAX. NUMBER OF FIBRES 48
• MAX. NUMBER OF CORES 6
• ARAMIDE STRENGTH ELEMENTS
• DIELECTRIC OR METALLIC CARRYING ELEMENT
• PE JACKET
• FOR GAP DISTANCES FROM 60 UP TO 200 M

The design of cables allows high tensile loads. The filled cores provide very good longitudinal waterproofing. The cables are delivered with metallic (steel wire) or dielectric (glass-laminate) carrying element. Maximal gap distance depends on wind conditions.

CONSTRUCTION:

Pic. 1

 

 

 

 

 

 

 

Transmission element

- optical fibre
- single-mode (SM) E9/125
- multimode (G) G50/125, G62,5/125

Secondary protection - loose, multi-fibre, filled tube

Cores - jelly filled tubes with fibres, stranded around dielectric central strength element

Strength elements - aramide fibres and dielectric central strength element

Jacket - black polyethylene

Carrying element - dielectric or steel wire

Tab. 1 Technical properties

Cable type A-DF(ZN)2YT2Y
Maximal number of cores with fibres 5 6
Number of fibres in tubes 1 to 8 1 to 8
Maximal number of fibres 40 48
Core diameter [mm] 2,4 2,4
Outer diameter [mm] 13 x 20 14,5 x 21,5
Maximal allowed tensile load [N] 7500 7,500
Minimal allowed bending radius [mm] 200 210
Permissible temperature range by mounting [°C] -5 to + 60 -5 to +60
Permissible temperature range in service[°C] -40 to +70 -40 to +70
Weight – informative value [kg/m] 200 210
Fibre type E9/125, G50/125, G62,5/125 E9/125, G50/125, G62,5/125
Outer jacket PE black PE black
Typical production lengths [m] 2000, 4000, 6000 2000, 4000, 6000


PACKING, DELIVERING, STORAGE, TRANSPORT

Optical cables are supplied twisted on wooden or metal drums with diameters of 500 to 1500mm, shorter lengths twisted to coils.

To every supplied length is attached test protocol and tag with these data:

- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control

The whole cable can be marked with description on a jacket on request of a client.

Cables can be stored in general in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them.

It is necessary to assure that cables are not damaged by mechanical or other effects by transport.