Skip to Content

A-DSF(ZN)2Y

APPLICATION

The cable is determined for outdoor aerial lines, for building of telecommunication networks, installation of LANs and cable TV networks and information systems in power engineering and industry. Pairs or quads can be used for telephonic connection, remote power supply, eventually for localization of cable line. Cable can be installed by blowing or pulling to protective tubes, pulling to cable ducts, putting into concrete blocks, eventually to sand bed or to cable trays.

PROPERTIES

• FULL DIELECTRIC CONSTRUCTION
• MAX. NUMBER OF FIBRES 84
• MAX. NUMBER OF CORES 8
• IN CABLE CORE INTEGRATED Cu PAIRS OR QUADS
• ARAMIDE STRENGTH ELEMENTS
• PE JACKET

The design of cables allows high tensile loads. The filled cores provide very good longitudinal waterproofing. Possibility of delivery also in flame retardant version according to IEC 332-3/I-DF(ZN)H/.

CONSTRUCTION

Pic. 1

 

 

 Transmission element - optical fibre
- single-mode (SM) E9/125
- multimode (G) G50/125, G62,5/125

Metallic conductor - pair or quad

Secondary protection - loose multi-fibre filled tube

Cores - consisted of filled tubes with fibres together with pair or quad stranded around dielectric central strength element

Strength elements - aramide fibres and dielectric central strength element

Jacket - black polyethylene

Tab. 1 Technical properties

Cable type A-DSF(ZN)2Y
Maximal number of cores with fibres 4 5 7
Number of pairs or quads 1 to 4 1 to 5 1 to 7
Number of fibres in tubes 1 to 8 9 to 12 1 to 8 9 to 12 1 to 8 9 to 12
Maximal number of fibres 32 48 40 60 56 84
Core diameter [mm] 2,4 3 2,4 3 2,4 3
Outer diameter [mm] 11,5 13 12,5 14 14 16
Maximal allowed tensile load [N] 2500
Minimal allowed bending radius [mm] 200 230 210 240 240 280
Permissible temperature range by mounting [°C] -5 to +55
Permissible temperature range in service [°C] -30 to +70
Weight – informative value [kg/m] 110 140 130 160 150 180
Fibre type E9/125, G50/125, G62,5/125
Outer jacket PE black
Typical production lengths [m] 2000, 4000, 6000


PACKING, DELIVERING, STORAGE, TRANSPORT

Optical cables are supplied twisted on wooden or metal drums with diameters of 500 to 1500mm, shorter lengths twisted to coils.

To every supplied length is attached test protocol and tag with these data:

- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control

The whole cable can be marked with description on a jacket on request of a client.

Cables can be stored in general in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them.

It is necessary to assure that cables are not damaged by mechanical or other effects by transport.