A-D(ZN)2Y
APPLICATION
The cable is determined for installation of LANs, cable TV networks and highest quality multimedia transmissions for telecommunication connection. Cable can be installed by blowing or pulling to protective tubes, pulling to cable ducts, putting into concrete blocks, eventually to sand bed or to cable trays.
PROPERTIES
• FULL DIELECTRIC CONSTRUCTION
• MAX. NUMBER OF FIBRES 12
• CENTRAL FILLED TUBE
• ARAMIDE STRENGTH ELEMENTS
• PE JACKET
Cables have due to their design low weight, dimensions and high tensile strength. It belongs to the cheapest solution of optical transmission line. It can be delivered also with double jacket, eventually with FRNC jacket and with metallic rodent protection.
CONSTRUCTION
Pic. 1

Transmission element - optical fibre
- single-mode (SM) E9/125
- multimode (G) G50/125, G62,5/125
Secondary protection - loose multi-fibre filled tube
Cores - consisted of central filled tubes with fibres
Strength elements - dielectric
- Standard construction- aramide
- Enforced construction - aramide fibres and sticks
Jacket - black polyethylene
Tab. 1 Technical properties
| Cable type | A-D(ZN)2Y | |
| Number of fibres in tubes | 2 to 12 | |
| Core diameter | [mm] | 3 |
| Outer diameter | [mm] | 9 |
| Maximal allowed tensile load | [N] | 1500 |
| Minimal allowed bending radius | [mm] | 120 |
| Permissible temperature range by mounting | [°C] | -5 to +55 |
| Permissible temperature range in service | [°C] | -25 to +55 |
| Weight – informative value | [kg/km] | 64 |
| Fibre type | E9/125, G50/125, G62,5/125 | |
| Outer jacket | PE black | |
| Typical production lengths | [m] | 2000, 4000, 6000 |
PACKING, DELIVERING, STORAGE, TRANSPORT
Optical cables are supplied twisted on wooden or metal drums with diameters of 500 to 1500 mm, shorter lengths twisted to coils.
To every supplied length is attached test protocol and tag with these data:
- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control
The whole cable can be marked with description on a jacket on request of a client.
Cables can be stored in general in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them.
It is necessary to assure that cables are not damaged by mechanical or other effects by transport.