CE 4 mm2
APPLICATION
Conductors insulated with polyethylene with a solid Cu core are used as identification conductors of gas and water plastic pipelines and they are designated for placing under the ground (STN 38 6415 č. 3.9).
Conductors CE 4 mm2 are produced and distributed according to PN VUKI 21 002.
MARKING
A cable mark consists of characters, which indicate mainly used materials and a cable construction:
1. character C - copper core
2. character E - insulation out of solid PE
CONSTRUCTION
Pic. 1 Cable construction

1 Solid Cu core with nominal diameter 2,24 mm.
2 Insulation out of solid PE. Insulation colour is black. Diameter over insulation is 3,9 ± 0,2 mm..
Tab. 1 Technical properties
| Insulation resistance by 20 °C | [Ω.km] | min. 5.109 |
| Conductor electrical resistance | [Ω.km] | max. 4,61 |
| Test voltage by 50 Hz/2 min | [kV] | min. 1 |
| Temperature range for fixed laying | [°C] | -40 to +50 |
PACKING, DELIVERING AND STORAGE
Cables are delivered usually in coils in lengths of 200 m.
It is safe to manipulate with cables at temperature range -10 °C to +50 °C.