Skip to Content

J-Y(St)Y

APPLICATION

Cables J-Y(St)Y are designated for internal, solid distribution in telecommunication engineering, for signal and data transmission and for electronic fire signalizing. Cables can be placed under a plaster.
Cables are produced according to VDE 0815.


MARKING EXAMPLE

J-Y(St)Y 10x2x0,6

Cable with ten Cu pairs with diameter 0,6 mm.


CONSTRUCTION

1 Solid copper core with diameter 0,6 or 0,8 mm.

2 Insulation is of PVC. Conductors are twisted to pairs. Pairs are mutually twisted in positions. Number of pairs is 1 to 30. Nominal insulation thickness is stated in table 2.
Colour marking of conductors is in table 1.

3 Cable core is wrapped with belt insulation of separative foil.

4 Screening of A1-PET foil oriented with metal inwards. There is minimal 1 CuSn wire under the foil.

5 White or grey PVC jacket. (For EPS red jacket.)

Tab. 1 Colour marking of conductors

Conductor  a Conductor  b

By first (counting) pair

in every position red,

pri by other pairs white

Number of pair colour
1 6 11 16 21 26 blue
2 7 12 17 22 27 yellow
3 8 13 18 23 28 grenn
4 9 14 19 24 29 brown
5 10 15 20 25 30 black

By 2-pair cable with cross quad build-up is:

in pair 1
conductor a red
conductor b black

in pair 2
conductor a white
conductor b yellow

Pair counting starts in upper position with colour distinguished counting pair. Pair counting continues in the same direction in every inner position.

Tab. 2 Technical properties

Nominal voltage [V] 300
Test voltage conductor/conductor [V] 800
Test voltage conductor/screening [V] 800
Allowed service temperature [°C] -40 up to + 70
Maximal loop resistance [Ω/km] 130 (0,6 mm) 73,2 (0,8 mm)
Minimal core insulation resistance [MΩ.km] 100
Service capacity of pair by 800 Hz [nF/km] 100
Maximal capacity unbalance by800 Hz [pF/100 m] 300

Construction

Nominal thickness
of conductor
insulation
[mm]

Nominal jacket
thickness
[mm]

External perimeter
(inf.)
[mm]

Weight
(inf.)
[kg/km]

2x2x0,6 0,16 0,8 4,5 35
4x2x0,6 0,16 0,8 5,9 50
5x2x0,6 0,16 1,0 6,4 60
6x2x0,6 0,16 1,0 6,8 75
10x2x0,6 0,16 1,0 8,2 105
16x2x0,6 0,16 1,0 9,6 150
20x2x0,6 0,16 1,0 10,2 180
24x2x0,6 0,16 1,0 11,3 210
30x2x0,6 0,16 1,2 12,6 265
1x2x0,8 0,31 0,8 5,4 40
2x2x0,8 0,31 0,8 6,1 55
4x2x0,8 0,31 1,0 8,4 95
5x2x0,8 0,31 1,0 9,3 115
6x2x0,8 0,31 1,0 9,8 130
10x2x0,8 0,31 1,2 12,4 205
16x2x0,8 0,31 1,2 14,7 300
20x2x0,8 0,31 1,2 15,7 355
24x2x0,8 0,31 1,4 17,7 435
30x2x0,8 0,31 1,4 19,2 525


PACKING, DELIVERING AND STORAGE

Cables are delivered in coils, greater lengths in drums.

Every delivered size should have a tag with these data:
- producer’s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control

Cables can be stored in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them. It is safe to manipulate with cables at temperature range -10 °C to +50 °C.