Skip to Content

TCEKF... 2 x 2 x 0,8 special

APPLICATION

Plastic twisted cable for video-signal transmission TCEKF...2 x 2 x 0,8 is designated for video-signal transmission for 2000m distance in electronic security systems. According to type, the cable is designated for indoor or outdoor use, for setting into ducts, for environment with increased corrosive aggressiveness STN 330300 čl.3.2.5, for burying to earth. On request of customer, the cable can be produced with halogen-free, flame retardant jacket, whereby this construction meets IEC 322-3A.

MARKING

Cable mark consists of characters, which indicate mainly used materials and cable construction:

TCEK + next character in sequence:

5. F - screening of plated leafs

6. E - PE jacket
Y - PVC jacket

Complete cable marking contains besides character mark also entry about number of pairs n and entry about nominal core diameter m in mm.

Marking example:
TCEKFY 2 x 2 x 0,8

Two-pair cable with conductor cores with diameter 0,8mm and with PVC jacket

CONSTRUCTION

1 Cores are out of copper wires with nominal diameter 0,8 mm.

2 Insulation is out of PE. Conductor insulation colour, which distinguishes conductors and pairs, is:
1. pair - blue and natural
2. pair - red and green
Colour marking can be different based on mutual agreement of manufacturer and customer. One pair is used for video-signal transmission, second one is power supply. Pairs are equivalent; it is possible to change them.

3 Screening jacket (in cable version with screening "F") is created of bottom longitudinally overlapped, resp. wrapped PET or PET+A1 layer oriented with metal outside and upper wrapped PET+Al layer oriented with metal inwards. Minimal thickness of A1 layer on screening layer is 0,012 mm. Continuity of foil is assured minimally with one additional tinned Cu wire with nominal diameter min. 0,4 mm.

4 Jacket is made of solid PE, resp. PVC. Jacket colour is black. Nominal jacket thickness is 1,2 mm.

Tab. 1 Technical properties

Insulation resistance [Ω.km] min. 5.109
Electrical conductor resistance [Ω.km] max. 37,5
Operating pair capacity [nF/km] max. 50

Nominal attenuation

256 kHz

1 MHz

5 MHz

10 MHz

20 MHz

[dB/100 m]

1,2

1,7

3,0

4,0

6,0

Test voltage by 50 Hz/2 min

between conductor cores

between conductor cores and screening

[kV]

min. 1

min. 2

PACKING, DELIVERING AND STORAGE

Cables are delivered in production length on wooden or metal drums. Smaller lengths can be delivered also in coils.

Cables can be stored in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them. It is safe to manipulate with cables at temperature range -10 °C to +50 °C.