VCCJE-R, VCXOE-R, VLXOE-R, VCXDE-R, VLXDE-R, VCXJE-R

APPLICATION

Cables substitute: VCCJY, VLEOY, VLEJY, VCEOY, VLEDY

Coaxial cables with lower inflammability and higher resistance to fire propagation according to STN IEC 60332-1, STN IEC 60332-3 non-halogen, with low smoke density by burning according to STN IEC 61034-2 and low corrosivity of combustion gases according to STN IEC 60754-2. Cables are designated for tertiary networks CATV, for rising wiring, for satellite reception and home TV and radio signal distribution in an environment with higher fire hazard. Cables can be installed also on flammable base.

CONSTRUCTION

Pic. 1


1 Vnútorné Inner copper core single-wired or multi-wired.

2 Dielectric out of cross-linked PE or PPE.

3 Screening

  • type J - Al-PET foil and CuSn wires braiding with 50% coverage
  • type O - Cu wires braiding with min.91% coverage
  • type D - double Cu wires braiding with » 99 % coverage (coverage of every braiding is min. 90%).

4 Non-halogen flame retardant PE jacket.

Tab. 1 Technical properties VCCJE-R, VCXJE-R, VCXOE-R, VCXDE-R, VLXOE-R, VLXDE-R

75-3,7 meets STN IEC 60332-3

Typ kábla

VCCJE-R

VCXJE-R

VCXOE-R

VCXDE-R

VLXOE-R

VLXDE-R

Core diameter [mm] 0,8 0,6 0,6 0,6 0,63 0,63
Insulation diameter [mm] 3,7 3,7 3,7 3,7 3,7 3,7

Outer cable diameter [mm]

6,4 6,4 6,4 7,0 6,4 7,0
Weight [kg/km] 50 55 60 65 60 65
Min.bending radius [mm] 60 50 40 40 30 30

Screening attenuation
up to 1000 MHz [dB]

>75 >75 >35 >60 >35 >60

Attenuation by 20 °C, max.
200 MHz
400 MHz
800 MHz
1700 MHz
[dB/100 m]

11,9
17,2
25,5
38,2

14,2
21,9
33,8
55,0

14,2
21,9
33,8
55,0

14,2
21,9
33,8
55,0

20,0
28,0
42,0
66,0

20,0
28,0
42,0
66,0

Tab. 2 Technical properties VCCJE-R, VCXJE-R, VCXOE-R, VCCJE-R, VCXOE-R

75-4,8 meets STN IEC 60332-3 75-7,25 meets STN IEC 60332-1
Cable type

VCCJE-R

VCXJE-R

VCXOE-R

VCCJE-R

VCXOE-R

Core diameter [mm] 1,1 0,75 0,75 1,6 1,15
Insulation diameter [mm] 4,8 4,8 4,8 7,25 7,25

Outer cable diameter [mm]

7,4 7,4 7,4 11 11
Weight [kg/km] 65 70 75 140 145
Min.bending radius [mm] 60 50 50 100 100

Tlmenie tienením do 1000 MHz [dB]

>75 >75 >35 >75 >35

Attenuation by 20 °C, max.
200 MHz
400 MHz
800 MHz
1700 MHz
[dB/100 m]

9,3
13,2
19,5
30,1

11,5
17,6
25,9
39,6

11,5
17,6
25,9
39,6

6,3
9,4
14,0
22,0

9,0
14,0
20,0
33,0

Tab. 3 Electrical properties

Characteristic impedance [Ω] 75 ± 3
Velocity ratio - PE 0,66
PPE 0,81
Operating temperature [°C] -20 až +85

DELIVERING, PACKING, STORAGE AND TRANSPORT

All cable types are supplied according to relevant company standards, twisted into coils, eventually greater lengths on wooden or metal drums. Every length is marked with tag with these data:

- producer´s mark
- cable identification
- cable length in meters
- production date
- stamp of quality control

The whole cable can be marked with description on a jacket on request of a client.

Cables can be stored in open-air area or in warehouses. They cannot be exposed to thermal radiation and they cannot be stored together with flammable liquids or solvents or with products containing them. It is safe to manipulate with cables at temperature range -10 °C to +50 °C.