Skip to Content

VCCOY 75-3,7 VCCOY 75-4,8 VCCOY 75-7,25 VCCOD 75-4,8

  • Capacitance: 54 pF/m
  • Velocity ratio: 0,81
  • Insulation material: foam polyethylene
  • Jacket material: PVC (type VCCOY) or double PE+PVC Jacket (type VCCOD)
  • Centre conductor: plain Cu wire
  • Outer conductor: braiding out of Cu wires with coverage > 91 %
  • Application: for TV cable distribution, mutual and individual satellite, television and radio distribution

 

Pic. 1 

 

 

 

 

 

 

 

Pic. 2

 

 

 

 

 

 

 

Tab. 1 Technical properties

Cable type

VCCOY 75-3,7

VCCOY 75-4,8

VCCOY 75-7,25

VCCOD 75-4,8

Cable type according to

RG MIL-C-17

RG59 RG6 RG11 RG6
Characteristic impedance [Ω] 75 ± 2 75 ± 2 75 ± 2 75 ± 2

Nom. attenuation taken at 20 °C

and frequency in MHz:

200

450

800

1750

(measured values)

[dB/100 m]

15,0

23,0

33,5

52,0

12,0

18,0

26,5

41,5

8,5

12,5

19,0

32,0

12,0

18,0

26,5

41,5

Screening efficiency

up to 1000 MHz [dB]

≥ 35 ≥ 35 ≥ 35 ≥ 35

Minimal bending radius [mm]

25 30 40 40
Max. permissible pulling force [N] 60 70 90 75
Weight [g/m] 46 64 122 104

Diameter of central conductor[mm]

0,8 1,1 1,6 1,1

Diameter over dielectric [mm]

3,7 4,8 7,25 4,8
Diameter of jacket mm] 6 7 10,3 8,5